1KW - 10MW Electric Generator Load Bank Testing Test Output Power Of Generator

Brand Name : Fullde
Model Number : LB-1000KW-400V
Certification : CE, ISO9001
Place of Origin : Dongguan,China
MOQ : one set
Price : Negotiable
Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability : 100 Set/Sets per Month
Delivery Time : 25 working days
Packaging Details : Packaged by Wooden Case with Soft Protective Material
Cooling Mode : Forced Air Cooling, Horizontal Inlet Air And Upwards Exhaust Cooling
Accessories : Switch: ABB, Siemens And Schneider, PLC: Panasonic And Siemens;
Way Of Working : Continuous Working
Load Tolerance : ±5%
Dimensions : 3000*2000*2000
Weight : 2000kg
Power : Electric
Contact Now

Container Type 1000KW-400V Generator Load Bank for 800KW Generator


Typical Applications:


1. In the acceptance inspection of load bank, the relevant department have to check whether the new devices fulfill the actual requirement.


2. After the installation of noise reduction devices, the loading capability must be test again.


3. For the routine test & maintenance, it is essential to test the output power and loading capability.


Main features of the generator load bank:


1. Power: 1KW-10MW


2. PF: 0.8-1.0


3. Fans cooling or water cooled


4. Inductive / Resistive or non-inductive


5. Manual/PLC remote control


6. Load steps(by switches) / infinite adjust


7. Current: 0.1A-10000A


8. Working voltage: DC/AC 1V-1000V


9. Value: 0.01Ω-100KΩ


10. Working Environment:
Altitute: ≤2500m
Temperature: -10°C~50°C
Humidity: ≤95%RH
Working Mode: Continuous work


11. IP class: IP20-IP67


12. Nice appearance, reasonable structure;
Good sealing: be able to work under rain, snow, dust, or any other harsh environment.


Introduction of the generator load bank:


Power generator intelligent testing system can accurately test the output power and loading capacity of various generator units,test all the electric parameters including dynamic parameters of generator units,and mainly consists of two parts:testing control and load cabinet,which is used in coordination with host computer thus materializing intelligentization and automatization to complete the testing of all electric parameters of generator unit,meanwhile,charts,curves and testing report are produced,and no manual operation is required(intelligently controlled,manual/automatic may be selected),to provide scientific testing means for large power generator units.


Technical Parameters for reference:

System componentsLoad bank, resistive load,data collection, automatic control and manual control, electrical control, cooling devices and auxiliary control,Industrial machines, printer.
Total discharge power1000KW
Resistive load stallsstep: 5KW
Test voltageThree-phase AC400V
Test Frequency50Hz
Resistance tubeInsulation resistance of each resistor above DC500V 100MΩ , Pressure AC2000V 1 minute, Resistance to high temperature.
Load connectionStar (three-phase four -wire)
Loading precision±3%
Work wayContinuous work
Working power480VAC/50Hz/Three-phase four-wire system; (reservation terminals)
Operator terminalIPC / software, full realization of automated control
Control modeManual control / computer software auto control
Measured Control FunctionLoad subtraction control, extended load automatic identification synchronization control
IPC detection functionI, V, HZ, KW, COSΦ etc.Real-time display, electrical performance testing, curves and report output, system electrical parameters monitoring, automatic data acquisition;
Parameter recordForm through EXCEL, curves pictures saved by WORD document
Parameter displaythree-phase voltage, three- phase current, apparent power, active power, reactive power, power factor, frequency, etc.;
Load protectionOvervoltage, overcurrent, high temperature, air flow and fan failure protection;
Fault alarmFan failure, load high temperature alarm
Dimension3000*2000*2000
Weight2000kg
Applicable ScopeFor marine diesel generator sets, land diesel generators, power inverters, UPS systems



Product Tags:

generator testing load bank

      

portable generator load bank

      
China Customized Inflatable Bumper Ball Game Bubble Adult Grass CE supplier

1KW - 10MW Electric Generator Load Bank Testing Test Output Power Of Generator Images

Inquiry Cart 0
Send your message to this supplier
 
From:
Enter your email please.
To: Guangdong Fullde Electrical Technology Co., Ltd
Subject:
Message:
Characters Remaining: (0/3000)
 

Home| Products| Suppliers| Quality Suppliers| Site Map |About Us |Contact Us |Help |关于我们 |联系我们

Copyright © 2009 - 2017 bjjsgy.com. All rights reserved.